NetApp - ONTAP MetroCluster Installation (NA-MCCIIW)

Next Date:
16.05.2024 - 09:00 - 16:00 Uhr
Course ends on:
17.05.2024
Total Duration:
16 Stunden in 2 Tagen
Internship:
Nein
Teaching Languages:
  • Deutsch
Type of Course:
  • Weiterbildung 
Type of Provision:
  • E-Learning 
Execution Time:
  • Tagesveranstaltung
min. Participants:
1
max. Participants:
8
Price:
€2,142 - Inklusive Schulungsunterlagen und Pausenversorgung
Funding:
  • Bildungsscheck Brandenburg für Beschäftigte 
  • Betriebliche Weiterbildung Brandenburg 
Type of Qualification:
Zertifikat/Teilnahmebestätigung 
Final Examination:
Nein
Qualification Title:
keine Angaben
Certifications of the Course:
  • Nicht zertifiziert
Courses for Women only:
Nein
Childcare:
Nein
Link to Course:
Quantity of Details:
Suchportal Standard nicht erfüllt - further information

Target Groups:
NetApp customers, partners, and employees.
Professional Requirements:
Kenntnisse entsprechend der Kursinhalte von ONTAP 9 Cluster Administration (ONTAP9ADM) und ONTAP 9 Data Protection Administration (DATAPROT9), Basic SAN knowledge.
Technical Requirements:
Keine besonderen Anforderungen.
Classification of the Federal Employment Agency:
  • C 1430-10-10 System-, Netzwerkadministration - allgemein

Contents

- Module 1: MetroCluster Overview
- - MetroCluster Introduction: Define MetroCluster, Describe MetroCluster Architecture, Configuration Replication Service (CRS), Limitations
- - MetroCluster supported configuration: Controllers, Shelves, Switches and ISL configuration, FAS8020, FAS8040, FAS8060 and FAS8080EX, FlexArray virtualization support
- - MetroCluster implementation overview, Setup
- - MetroCluster configuration tools and documentation: Hardware, Materials, Technical content
- Module 2: MetroCluster Cabling
- - Disk requirements
- - Plex SyncMirror overview
- - Shelf IDs
- - Cabinet Layout
- - LUN layout with FlexArray storage virtualization software
- - ATTO FibreBridge
- - Cabling Shelves to Bridges
- - Cabling Bridges to FC switches
- - Controller Cabling: Cluster Interconnect, FC-VI Interconnect, Onboard ports or HBAs, CRS, Management and data LIFs
- - FC switch cabling
- - Switch alternatives: Brocade 6505 and 6510, Cisco 9148
- Module 3: Bridge and Switch Configuration
- - ATTO FibreBridge configuration
- - Brocade FC switch configuration
- - FC switches: Configuration, RCF domains, RCF ports and zone settings
- - Brocade ISL configuration: Calculating and setting distance, Verifying, OOD configuration - ONTAP 9 and later
- Module 4: Cluster Configuration
- - Controller configuration
- - Setup
- - Disk ownership
- - FlexArray storage virtualization software
- - Cluster setup
- Module 5: MetroCluster Configuration
- - MetroCluster setup: Prerequisites, Peer relationship, Mirror aggregates, Create mirrored data aggregates, Enable configuration replication, MetroCluster configure command
- - MetroCluster verification: Disk ownership fields, Monitor FC switches, Monitor FibreBridge devices, Cluster status, MetroCluster plug-in
- - CLI health monitoring: Node verification, Components, CRS component, Interconnect mirror
- - OnCommand unified manager: Connectivity monitoring, Replication monitoring, Events and alerts
- - SVM configuration in a MetroCluster environment: Setup, CLI, Automatic creation
- Module 6: Failure Scenarios
- - Failures: Bridge, Switch or switch port, Single path, Shelf, CRS, ISL, Single HA node, Double HA node, Data center site
- - Switchover types: Simulation, Negotiated switchover, Non-negotiated switchover, Switchover operation, Switchback
- - Switchback process
- Module 7:Tiebreaker Configuration
- - Tiebreaker software
- - Disaster Detection
- - Normal operation
- - Tiebreaker installation: Service operations, Configuration, Commands, Monitor creation, AutoSupport, SNMP

All statements without guarantee. The providers are solely responsible for the correctness of the given information.

Published on 26.03.2024, last updated on 16.05.2024